Sign In | Join Free | My burrillandco.com
Home > MTL Safety Barrier >

HART MTL4541 MTL Safety Barrier Repeater Power Supply

SC Automation Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap HART MTL4541 MTL Safety Barrier Repeater Power Supply from wholesalers
     
    Buy cheap HART MTL4541 MTL Safety Barrier Repeater Power Supply from wholesalers
    • Buy cheap HART MTL4541 MTL Safety Barrier Repeater Power Supply from wholesalers
    • Buy cheap HART MTL4541 MTL Safety Barrier Repeater Power Supply from wholesalers
    • Buy cheap HART MTL4541 MTL Safety Barrier Repeater Power Supply from wholesalers
    • Buy cheap HART MTL4541 MTL Safety Barrier Repeater Power Supply from wholesalers
    • Buy cheap HART MTL4541 MTL Safety Barrier Repeater Power Supply from wholesalers

    HART MTL4541 MTL Safety Barrier Repeater Power Supply

    Ask Lasest Price
    Brand Name : MTL
    Model Number : MTL4541
    Certification : CE
    Price : negotiable
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : on request
    • Product Details
    • Company Profile

    HART MTL4541 MTL Safety Barrier Repeater Power Supply

    MTL4541 REPEATER POWER SUPPLY

    The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.


    SPECIFICATION

    Number of channels

    One

    Location of transmitter

    Zone 0, IIC, T4–6 hazardous area if suitably certified

    Div. 1, Group A hazardous location

    Safe-area output

    Signal range: 4 to 20mA

    Under/over-range: 0 to 24mA

    Safe-area load resistance (MTLx541)

    @ 24mA: 0 to 360Ω

    @ 20mA: 0 to 450Ω

    Safe-area load (MTLx541S)

    Current sink: 600Ω max.

    Maximum voltage source: 24V dc

    Safe-area circuit output resistance: > 1MΩ

    Safe-area circuit ripple

    < 50µA peak-to-peak

    Hazardous-area input

    Signal range: 0 to 24mA (including over-range)

    Transmitter voltage: 16.5V at 20mA

    Transfer accuracy at 20°C

    Better than 15µA

    Temperature drift

    < 0.8µA/°C

    Response time

    Settles to within 10% of final value within 50µs

    Communications supported

    HART (terminals 1 & 2 only)

    LED indicator

    Green: power indication

    Maximum current consumption (with 20mA signal)

    51mA at 24V

    Power dissipation within unit (with 20mA signal)

    MTLx541 0.7W @ 24V dc

    MTLx541S 1.0W @ 24V dc

    Safety description

    Terminals 2 to 1 and 3:

    Uo =28V Io =93mA Po =651mW Um = 253V rms or dc Terminals 1 to 3:

    Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected without further certification into any IS loop with an open-circuit voltage <28V


    Related Part Number:


    HCU16MTL5521MTL4546YMTL7761PAC
    HCU3700MTL5522MTL4549YMTL7765AC
    HM64RIB20-1.0MTL5531MTL4573MTL7787+
    HM64RIB20-1.5MTL5532MTL4575MTL7787P+
    HMM64MTL5541MTL4646YMTLCPS16
    HMRIB16-1.0MTL5541SMTL4850NJ5-18GK-N
    HMS64MTL5544MTL4851SD150X
    HTP-SC32MTL5544DMTL4852SD32
    MTL4044DMTL5546MTL5018SD32X
    MTL4511MTL5546YMTL5032SDRTD
    MTL4516MTL5561MTL5042SLP32D
    MTL4516CMTL5573MTL5044TP48-3-I-NDI
    MTL4521MTL5575MTL5049TP48-3-N-NDI
    MTL4541MTL5582BMTL5511TP48-4-I-NDI
    PCL45USBMTL7728+MTL5514DTP48-4-N-NDI
    MTL4544MTL7756ACMTL5516TP48-N-NDI
    MTL4544DMTL7760ACMTL5516CZB24571

    HART MTL4541 MTL Safety Barrier Repeater Power Supply

    Quality HART MTL4541 MTL Safety Barrier Repeater Power Supply for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SC Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)